TACOMETRO 96X48 DIG. 5D. ENT. 100-240VAC Cod.: RP3-5AN
Suffix code Model name | Suffix code | Description | RP | - |  |  |  | Mulit Pulse Meter | Size | 1 | | | | 48(W) x 24(H) x 100(D) mm | Displayable Digits | 4 | | | 4 digits 1 stage | Power Supply Specification | A | | 100 - 240 a.c(50 - 60 Hz) | D | | 24 - 60 V a.c / d.c | Output Specification Size-6 | N | Only display | 1 | Relay Upper-limit Output |
Model name | Suffix code | Description | RP | - |  |  |  | Mulit Pulse Meter | Size | 4 | | | | 48(W) x 48(H) x 79.3(D) mm | Displayable Digits | 5 | | | 5 digits 1 stage | Power Supply Specification | A | | 100 - 240 a.c(50 - 60 Hz) | D | | 24 - 60 V a.c / d.c | Output Specification Size-6 | N | Only display | 1 | Relay Upper-limit Output |
Model name | Suffix code | Description | RP | - |  |  |  | Mulit Pulse Meter | Size | 6 | | | | 72(W) x 36(H) x 100(D) mm | Displayable Digits | 5 | | | 5 digits 1 stage | Power Supply Specification | A | | 100 - 240 a.c(50 - 60 Hz) | D | | 24 - 60 V a.c / d.c | Output Specification Size-6 | | Main output | Subsidiary output | N | Only display | - | 1 | Relay 3 stages Output | - | 3 | NPN Open Collector 5 Stages Output | 4 - 20 mA Current Output |
Model name | Suffix code | Description | RP | - |  |  |  | Mulit Pulse Meter | Size | 7 | | | | 72(W) x 72(H) x 87(D) mm | Displayable Digits | 5 | | | 5 digits 1 stage | Power Supply Specification | A | | 100 - 240 a.c(50 - 60 Hz) | D | | 24 - 60 V a.c / d.c | Output Specification Size-6 | | Main output | Subsidiary output | N | Only display | - | 1 | Relay 3 stages Output | - | 2 | Relay 5 stages Output | - | 5 | NPN Open Collector 5 Stages Output | 4 - 20 mA Current Output |
Specification Model | RP3 | RP4 | RP6 | RP7 | Appearance(mm) | | | | | 96(W) x 48(H) x 100(D) | 48(W) x 48(H) x 100(D) | 72(W) x 36(H) x 100(D) | 72(W) x 72(H) x 100(D) | Function | ·Auto Zero time setting function | ·Time unit selection function | ·Parameter lock function | ·Power failure compensation function | ·Remote/local conversion function | (applicable only for F9) | (applicable only for communication output type) | ·Comparative output function (HH, H, GO, L, LL) | ·4 steps bank setting function | ·Current output range selection function | ·Max, Min, Peak value 10 steps memory display function | (Max : 4 steps save, average value save, Min : 4 steps save, average save) | ·Starting compensation timer function | ·Display cycle setting function |
| Power Supply | 110 - 240 V a.c(50 - 60 Hz) | 24 - 60 V(d.c / a.c) 50 - 60 Hz | Power Consumption | Below 9.5 VA(240 V a.c) | Below 12 VA(240 V a.c) | Below 9.5 VA(240 V a.c) | Below 5 W (24 V d.c) | Below 6 W (24 V d.c) | Below 5 W (24 V d.c) | Voltage output for Sensor | 12 V d.c ±10% 120 mA(voltage fluctuation rate ±10%) | Measuring Accuracy | FS ±0.01% rdg ±1dig | Measurement Range | 0.0005 Hz ~ 10 K Hz, 0.001 s ~ 3.200 s, 0 ~ 4 x 10 9 Count | Max. Diplayable Digits | 5 Digits(0 ~ 99999) | Display Method | 7 Segment | Input Signal | Non-Contact Input : Max. 10 kHz(ON/OFF width for each above 50 µs) | (ON voltage : 4.5 V ~ 24 V, OFF voltage : 0 ~ 1.0 V) | Contact Input : Max. 30 Hz(ON/OFF width for each above 33 ms) | (12 V d.c, able to switch the current of 2 mA sufficiently) |
| Output type | Relay Output(H, GO, L) (HH, H, GO, L, LL) | Relay Output(H) | Relay Output(H, GO, L) | Relay Output(H, GO, L) (HH, H, GO, LL) | Operation Mode | ·F1: revolution/frequency/speed | ·F2: moving speed | ·F3: cycle | ·F4: passing time | ·F5: time difference | ·F6: time width | ·F7: pulse width | ·F8: pulse interval |
| Noise Immunity | By noise simulator, square-shaped wave noise(pulse width 1 µs) ±2000 V | Vibration Resistance | Durability | :10~55Hz double amplitude width 0.75mm in each X·Y·Z direction for 2 hours | Malfunction | :10~55Hz double amplitude width 0.5mm in each X·Y·Z direction for 10 minutes |
| Shock Resistance | Durability | :300 m/s² (approx. 30G) in each X·Y·Z direction for 3 times | Malfunction | :300 m/s² (approx. 30G) in each X·Y·Z direction for 3 times |
| Operating Ambient Environment | Temperature: -10 ~ 50 °C(without condensation), Humidity: 35 ~ 85 % RH |